This seminar explains how grout transfers load, how cementitious and epoxy grouts behave and are tested, how to detail and place a grouting job so it achieves full bearing, and how to specify, install and verify bonded anchors and starter bars.
Learning objectives
- Explain how grout transfers load from base plates, bearings and machinery to the foundation, and how flow, bleed, volume change and effective bearing area decide success
- Compare cementitious and epoxy grouts and select between them by gap, load, vibration, temperature and chemical exposure
- Design the grouting detail, including gap and shoulder dimensions, formwork, head box, venting, expansion joints and placement method
- Specify anchoring of bolts and starter bars with resin or cementitious anchor grouts, including installation, curing and testing
Modules0 of 5 done
1
How grout carries the loadLoad paths, bearing area and why a thin layer under a machine matters · About 11 min · 8 min video
Watch
2
Cementitious grouts and testingNon-shrink grades, consistency, volume change and hot-weather placing · About 11 min · 6 min video
Watch
3
Epoxy grouts and grout selectionEpoxy grout properties and testing, and choosing between epoxy and cementitious · About 11 min · 6 min video
Watch
4
Designing the grouting detailGap, shoulder, formwork, head box, venting, joints and placement method · About 11 min · 5 min video
Watch
5
Anchoring bolts and starter barsResin and cementitious anchor grouts: design, installation, curing and testing · About 16 min · 7 min video
Watch
★
Assessment10 questions · pass mark 80% · 2 attempts